Abstracts – Browse Results

Search or browse again.

Click on the titles below to expand the information about each abstract.
Viewing 31 results ...

Adewumi, A S, Onyango, V, Moyo, D and AlWaer, H (2019) A review of selected neighbourhood sustainability assessment frameworks using the Bellagio STAMP. International Journal of Building Pathology and Adaptation, 37(01), 108–18.

Agyekum, K, Blay, K and Opoku, A (2019) Mechanisms for preventing rising damp in new building infrastructure. International Journal of Building Pathology and Adaptation, 37(01), 87–107.

  • Type: Journal Article
  • Keywords: Building infrastructure; Damp proof coatings; Damp proof courses; Dense concrete; Rising damp; Test wall;
  • ISBN/ISSN: 2398-4708
  • URL: https://doi.org/10.1108/IJBPA-06-2018-0048
  • Abstract:
    Capillary rise of water in buildings has been an issue of concern among past and present researchers. Despite the research efforts devoted to the proper elimination of the problem in masonry construction, it still remains a challenge that needs to be addressed. The purpose of this paper is to explore treatment mechanisms that can be used to prevent rising damp in new building infrastructure. Design/methodology/approach In total, 14 test walls are constructed, conditioned, subjected to various treatments and monitored for four years. The treatments applied to the walls include the use of polyethylene damp proof courses, damp proof coatings and dense concrete bases. The walls are then monitored with reference to the two climate seasons in Ghana. Findings The results highlight that rising damp is present, as suggested by the constant increase and decrease in the height of the water levels in the walls during the rainy and dry seasons, respectively. The findings further reveal that within the four-year period, the walls treated with the damp proof coatings, together with those with the dense concrete bases performed better than those treated with the polyethylene damp proof courses. Research limitations/implications The economic and commercial impact of these preventive mechanisms were not considered in this study. A future research can be directed at these issues. Practical implications The proposed treatment mechanisms highlight the effectiveness of some treatments applied to walls to prevent the capillary rise of water from the ground into the superstructure. Social implications Building regulations, especially in Ghana and other tropical settings should be amended to include ways to prevent rising damp phenomena by including effective methods against rising damp during the building design or construction. Originality/value Series of studies worldwide have been conducted in laboratories to simulate the capillary rise of water in walls of buildings. This is among the few studies that look at how water rises from actual ground conditions into the walls of buildings.

Ahmad Shazali, A S and Tahar, K N (2019) Virtual 3D model of Canseleri building via close-range photogrammetry implementation. International Journal of Building Pathology and Adaptation, 38(01), 217–27.

Al-Kheetan, M J, Rahman, M M and Chamberlain, D A (2018) Remediation and protection of masonry structures with crystallising moisture blocking treatment. International Journal of Building Pathology and Adaptation, 36(01), 77–92.

Alao, O O and Jagboro, G O (2017) Assessment of causative factors for project abandonment in Nigerian public tertiary educational institutions. International Journal of Building Pathology and Adaptation, 35(01), 41–62.

Ali, A S, Azmi, N F and Baaki, T K (2018) Cost performance of building refurbishment works: the case of Malaysia. International Journal of Building Pathology and Adaptation, 36(01), 41–62.

Amadi, A and Higham, A P (2019) A cost trajectory to environmentally adaptive building construction in wet humid settings. International Journal of Building Pathology and Adaptation, 38(01), 68–88.

Ashdown, M M, Crawley, J, Biddulph, P, Wingfield, J, Lowe, R and Elwell, C A (2019) Characterising the airtightness of dwellings. International Journal of Building Pathology and Adaptation, 38(01), 89–106.

Blay, K, Agyekum, K and Opoku, A (2019) Actions, attitudes and beliefs of occupants in managing dampness in buildings. International Journal of Building Pathology and Adaptation, 37(01), 42–53.

Crawley, J, Biddulph, P, Wingfield, J, Ashdown, M, Lowe, R and Elwell, C (2019) Inferring the as-built air permeability of new UK dwellings. International Journal of Building Pathology and Adaptation, 38(01), 3–19.

Djebbar, K E, Salem, S and Mokhtari, A (2019) Assessment of energy performance using bottom-up method. International Journal of Building Pathology and Adaptation, 38(01), 192–216.

Enshassi, A, Ayash, A and Mohamed, S (2018) Key barriers to the implementation of energy-management strategies in building construction projects. International Journal of Building Pathology and Adaptation, 36(01), 15–40.

Erkoreka, A, Flores-Abascal, I, Escudero, C, Martin, K, Millan, J A and Sala, J M (2019) Flat roof hygrothermal performance testing and evaluation. International Journal of Building Pathology and Adaptation, 38(01), 148–75.

Flood, C and Scott, L (2019) Thermal analysis and post construction verification. International Journal of Building Pathology and Adaptation, 38(01), 51–67.

Gerges, M, Mayouf, M, Rumley, P and Moore, D (2017) Human behaviour under fire situations in high-rise residential building. International Journal of Building Pathology and Adaptation, 35(01), 90–106.

Gupta, R, Gregg, M and Cherian, R (2019) Developing a new framework to bring consistency and flexibility in evaluating actual building performance. International Journal of Building Pathology and Adaptation, 38(01), 228–55.

Hamidane, H, Ababneh, A, Messabhia, A and Xi, Y (2019) Modeling of chloride penetration in concrete structures under freeze-thaw cycles. International Journal of Building Pathology and Adaptation, 38(01), 127–47.

Hosseini, M R, Roelvink, R, Papadonikolaki, E, Edwards, D J and Pärn, E (2018) Integrating BIM into facility management. International Journal of Building Pathology and Adaptation, 36(01), 2–14.

Ibraheem, Y, Piroozfar, P A, Farr, E R and Ravenscroft, N (2019) Methodological evaluation of Integrated Façade Systems. International Journal of Building Pathology and Adaptation, 38(01), 107–26.

Jandali, D and Sweis, R (2019) Factors affecting maintenance management in hospital buildings. International Journal of Building Pathology and Adaptation, 37(01), 6–21.

Kayan, B A (2017) Green maintenance for heritage buildings: paint repair appraisal. International Journal of Building Pathology and Adaptation, 35(01), 63–89.

Li, M, Allinson, D and Lomas, K (2019) Estimation of building heat transfer coefficients from in-use data. International Journal of Building Pathology and Adaptation, 38(01), 38–50.

Md Ali, Z, Zawawi, R, Myeda, N E and Mohamad, N (2019) Adaptive reuse of historical buildings. International Journal of Building Pathology and Adaptation, 37(01), 54–68.

O’Connell, S, Reynders, G, Seri, F, Sterling, R and Keane, M M (2019) A standardised flexibility assessment methodology for demand response. International Journal of Building Pathology and Adaptation, 38(01), 20–37.

Ogbeifun, E, Mbohwa, C and Pretorius, J C (2018) Developing an effective renovation plan: the influence of data collection tools. International Journal of Building Pathology and Adaptation, 36(01), 63–76.

Opawole, A and Jagboro, G O (2018) Compensation mechanisms for minimizing private party risks in concession-based public-private partnership contracts. International Journal of Building Pathology and Adaptation, 36(01), 93–120.

Rogage, K, Clear, A, Alwan, Z, Lawrence, T and Kelly, G (2019) Assessing building performance in residential buildings using BIM and sensor data. International Journal of Building Pathology and Adaptation, 38(01), 176–91.

Spennemann, D H, Pike, M and Watson, M J (2017) Effects of acid pigeon excreta on building conservation. International Journal of Building Pathology and Adaptation, 35(01), 2–15.

Sweis, R, Moarefi, A, Hoseini-Amiri, S and Moarefi, S (2019) Delay factors of the schedule of strategic industrial projects. International Journal of Building Pathology and Adaptation, 37(01), 69–86.

Tade, O, O’Neill, S, Smith, K G, Williams, T, Ali, A, Bayyati, A and See, H (2019) Modified sewer asset management to accommodate London’s future sustainable development. International Journal of Building Pathology and Adaptation, 37(01), 22–41.

Zuhaib, S, Manton, R, Hajdukiewicz, M, Keane, M M and Goggins, J (2017) Attitudes and approaches of Irish retrofit industry professionals towards achieving nearly zero-energy buildings. International Journal of Building Pathology and Adaptation, 35(01), 16–40.